Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera

  • Hamzah Eteruddin Universitas Lancang Kuning, Indonesia
  • Hendry Hendry Universitas Lancang Kuning, Indonesia
  • Atmam Atmam Universitas Lancang Kuning, Indonesia
DOI: https://doi.org/10.31258/ijeepse.1.2.1-5
Abstract viewed: 497 times
PDF downloaded: 391 times
Keywords: Power quality, Short circuit, Voltage sag

Abstract

Power quality is closely related to electrical energy which is directly related to voltage and current interference. Electrical equipment used daily requires good power quality. The thing that affects the quality of the power is the voltage dip. Based on the IEEE 1159-1995 standard, voltage sag is a decrease in RMS voltage with duration of 0.5 cycle to 1 minute. Sag voltage that occurs can have an effect on electronic equipment and other problems that often arise in the industrial environment. Therefore, a short circuit fault analysis was conducted to determine the voltage sag based on the type of fault in the sub system in Central Sumatera. Short circuit fault analysis is done using Powerworld Simulator 7.0 Students Edition. This study is intended to determine the sag voltage when there is a short circuit fault. The biggest voltage sag occurs when a short circuit fault of single phase to ground at 75% fault location and the smallest voltage sag when the three-phase short circuit of 0.7 fault location.

References

[1] M. H. J, "Bollen, Understanding Power Quality Problems, Voltage Sag and Interruptions", John Wiley, New York, 2000.

[2] B. W. Kennedy, "Power Quality Primer. New York", McGraw-Hill, 2000.

[3] R. S. Vedam, M. S. Sarma, "Power Quality: VAR Compensation in Power Systems", CRC Press, London, 2009.

[4] M. N. Sinha, B.R.Parekh, “Simulation of Voltage Sag Magnitude Estimation in a Power System Network,” Res. Rev. - Int. Journals Int. J. Adv. Res. Electr. Electron. Instrum. Eng., vol. 3, no. 2, pp. 7410–7415, 2014.

[5] R. C. Dugan, S. Santoso, M. F. McGranaghan, H. W. Beaty, "Electrical Power Systems Quality", 2nd ed. McGraw-Hill Education, 2002.

[6] A. Chowdhury and D. Koval, "Power Distribution System Reliability: Practical Methods and Applications", Wiley, New Jersey, 2011.

[7] IEEE and Institute of Electrical and Electronic Engineers, “IEEE Std 1159 - IEEE Recommended Practice for Monitoring Electric Power Quality", 2009.

[8] L. Zhang and M. H. J. Bollen, “A method for characterisation of three-phase unbalanced dips (sags) from recorded voltage waveshapes”, 21st International Telecommunications Energy Conference. INTELEC ’99 (Cat. No.99CH37007), p. 188, 1999.

[9] R. K. Sinha, R. Kumar, M. Venmathi, L. Ramesh, “Analysis of Voltage Sag with Different DG for Various Faulty Conditions,” Int. J. Comput. Commun. Inf. Syst., vol. 2, no. 1, pp. 189–193, 2010.

[10] I. K. P. Ross, “Voltage Sags an Explanation Causes, Effects, and Correction”, 2006.

[11] C. L. Wadhwa, "Electrical Power System", New Academic Science, 2012.

Published
2018-11-05
How to Cite
[1]
H. Eteruddin, H. Hendry, and A. Atmam, “Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera”, IJEEPSE, vol. 1, no. 2, pp. 1-5, Nov. 2018.